45221A
Printed in Canada 02-05-2012
OWNER`S MANUAL
Escape 1400-I Insert
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED
WOOD INSERT
Verified and tested following
ULC S628 and UL 1482 Standards by:
Manufactured by : STOVE BUILDER INTERNATIONAL INC..
250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3
Tel.: 418 878-3040 Fax: 418 878-3001
www.drolet.ca
READ AND KEEP THIS MANUAL FOR REFERENCE
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time
to time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - Escape 1400-I Insert

45221A Printed in Canada 02-05-2012 OWNER`S MANUAL Escape 1400-I Insert US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD INSERT

Strona 2 - INTRODUCTION

10 2.3 Installation Instructions 1. Inspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or

Strona 3 - TABLE OF CONTENTS

11 4. If lag-bolts and anchors are to be used to secure the insert, the hole locations should be marked with the unit in place. Remove the insert an

Strona 4 - Escape 1400-I Dimensions

12 2.5 Installation of the adapter for fresh air kit In order to avoid some combustion problems, it is highly recommended to install an adapter for f

Strona 5

13 Section 3.0 Operation 3.1 Safety Information 1. This insert is designed for safe operation WHEN BURNING CORDWOOD ONLY. Altering or modifying t

Strona 6

14 overheat the chimney and adjacent combustibles. Do not operate the insert if there is an abnormal air leakage into the unit, such as through deter

Strona 7 - Section 2.0 Installation

15 5. Decayed wood or low density wood has very little energy content or heating value, and will not burn satisfactorily for long periods of time. A

Strona 8

16 5. Light a fire at the bottom of the crumpled paper and close the door. If the fire tends to go out, momentarily hold the door slightly ajar to fa

Strona 9

17 3.5 Maintaining The Fire Your Drolet insert will work best if a thick bed of hot embers is maintained in the bottom of the firebox and a minimum o

Strona 10

18 Section 4.0 Maintenance 4.1 Care And Cleaning Clean the insert frequently so that soot, ash and creosote do not accumulate. Do not attempt to cl

Strona 11

19 4.2 Ash Removal CAUTION: Ashes can start fires, even after several days of inactivity. Never dispose of ashes in a combustible container. Remov

Strona 12

2 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to

Strona 13 - Section 3.0 Operation

20 4.4 Baffle Installation for Escape 1400-I Figure 4.1 – Baffle installation & removal for Escape 1400-I The baffle assembly must

Strona 14

21 4.5 Secondary Air Tube Replacement (see Figure 4.3) 1. Remove cotter pin at RH end of tube. 2. Slide tube to left and lower tube end below RH p

Strona 15

22 4.6 Fan Maintenance & Care Clean the fan air inlet louvres and squirrel cage impeller regularly. The fan should be kept clean and dust free.

Strona 16 - DAMPER OPERATION

23 Section 5.0 Specifications 5.1 Escape 1400-I Insert Model Fuel Type Cordwood Test Standards ULC S628 (CSA B366.2) & UL 1482 residen

Strona 17

24 DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This w

Strona 18 - Section 4.0 Maintenance

3 TABLE OF CONTENTS INTRODUCTION ... 2Section 1.0 Pre-Installation Require

Strona 19

4 Escape 1400-I Dimensions Faceplate fully extended toward the back Faceplate fully extended toward the front

Strona 20

5 Section 1.0 Pre-Installation Requirements 1.1 Masonry & Zero Clearance Requirements The masonry fireplace must meet the minimum code requiremen

Strona 21

6 1.2 Venting Requirements The flue is a critical component to a satisfactory installation. Your insert will attain its best performance if installe

Strona 22 - "ALTERING

7 Section 2.0 Installation 2.1 Minimum masonry opening, clearances to combustibles, and floor protector

Strona 23 - Section 5.0 Specifications

8 MINIMUM MASONRY OPENING F 21½” (546 mm)* G 29” (737 mm) H 14” (356 mm)* CLEARANCES A 13” (335 mm) B 10” (255 mm) C 22” (560 mm) D 29” (740 mm)

Strona 24

9 2.2 Safety Information NOTE: This appliance is not recommended for use in a home if an occupant has any respiratory or any other related problems.